TDK-Lambda RSEL-20R5AL Single Phase Power Line EMI Filter 250V 0.5A Base Mounting Quick Connector Low Leakage Current
VIEW PRICELog in to view your customer price
| Series | RSEL Series |
| Filter Type | Single-phase Power Line EMI/EMC Filter |
| Voltage | 250 VAC / 250 VDC (50/60Hz) |
| Rated Current | 500 mA (0.5 A) @ 40°C |
| Test Voltage | 1450 VDC (standard product) / 2250 VDC (medical low leakage current product with AL suffix) |
| Test Voltage (Line-Ground) | 2250 VDC |
| Leak Current | Maximum 0.01 mA (AL low leakage current specification) |
| Installation | Base Mounting / Flange Mounting |
| Connector Type | Faston Connector (6.3mm x 0.8mm) |
| Operating Temperature | -25°C to +85°C (Rated Current Derating to 85°C) |
| Fire Resistance Grade | UL94V-0 |
| Certification | UL 1283 (E70765), CSA C22.2 No.8 (LR46266), EN 60939 (VDE), RoHS Directive (2011/65/EU) |
| Material | Metal housing (galvanized steel plate) |
| Encapsulation Size | Approx. 46.5 x 25 x 21.5 mm (Refer to Data Manual Outline Drawing) |
| Weight | Approximately 35 g |
| Common Mode-Differential Mode Attenuation | 0.1MHz - 30MHz high attenuation characteristics (see data sheet attenuation curve) |
| Application Scenario | Switched-mode power supply input, industrial control board card, medical device power entry |
Manufacturer No.
RSEL-20R5ALRSEL20R5AL
OEM Part No.
B84776M0001A000
Interchange No.
RSAL-20R5ALRSEL-20R5ARSEL-20R5WRSEL-20R5WL
Fitment Vehicles
Universal Industrial Power SupplyMedical Power Supply EquipmentTest and Measurement InstrumentsAutomated Control Cabinet
Electrical and Electronic System - Industrial Encyclopedia
TDK-Lambda RSEL-20R5AL Single Phase Power Line EMI/EMC Filter, rated voltage 250VAC/VDC, rated current 500mA (0.5A), base/flange mounting, quick connection terminal (Faston). Compliant with RoHS, UL, CSA, EN 60939 certification, low leakage current design, suitable for general electromagnetic compatibility suppression scenarios in industrial power supplies, medical equipment, testing and measuring instruments, etc. Complete data manual and reliability report provided.