XZR8®
TDK-Lambda RSEN-2006LD Single Phase Power Line Filter 6A 250VAC DIN Rail Mount

TDK-Lambda RSEN-2006LD Single Phase Power Line Filter 6A 250VAC DIN Rail Mount


VIEW PRICE
Log in to view your customer price
Rated Current6A
Voltage250VAC / 250VDC (50/60Hz)
Phase CountSingle-Phase
InstallationDIN rail mounting (compatible with TS-35/EN60715), chassis bottom plate mounting
Connection TypeScrew Terminal / Terminal Block
Leak Current CharacteristicStandard Type / Optional Low Leakage Current Type
Operating Temperature-25°C ~ +85°C (Reduced Usage Required)
Storage Temperature Range-40°C ~ +85°C
Safety CertificationUL1283 (E62388), CSA C22.2 No.8, EN60939-2 (VDE), RoHS, REACH
Over Pressure CategoryII (IEC 60664-1)
Pollution Grade2
Pressure Test StandardWire-to-Wire: 1450VDC / Wire-to-Ground: 2250VDC (1 minute)
Fire Resistance GradeUL94V-0 (housing and resin)
Mean Time Between Failures> 1,000,000 hours (MIL-HDBK-217F, 25°C)
MaterialMetal Shell (Excellent Shielding Effect)
Manufacturer No.
RSEN-2006LDRSEN-2006DRSEN-2006LRSEN-2006

Electrical and Electronic System - Industrial Encyclopedia

TDK-Lambda RSEN-2006LD Single Phase Power Line EMI Filter, rated current 6A, rated voltage 250VAC/DC, standard DIN rail (TS-35) installation, screw terminal wiring, compliant with UL1283/CSA/EN60939 safety standards, RoHS/REACH compliant, optional low leakage current design, widely used for industrial automation power supplies, inverters, servo drives and EMC conduction interference suppression for general electronic equipment.